← All CVEs

CVE-2026-40633

HIGH 7.8

Published 2026-07-15 · Last modified 2026-07-15

Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.

ELEVATED IMPACT

Severe if exploited (CVSS 7.8), but no known exploitation and low modeled probability. Patch on a normal cadence.

Exploitation likelihood

0.1%chance of exploitation in 30 days · 1st percentile

○ In CISA KEV ○ Public exploit / PoC

Impact if exploited

7.8CVSS 3.1 · HIGH

  • ConfidentialityHigh
  • IntegrityHigh
  • AvailabilityHigh

What an attacker needs

  • Access: Requires local access to the host
  • Privileges: Requires a low-privilege account
  • User interaction: No user interaction needed
  • Complexity: No special conditions — reliably repeatable

✓ lowers the bar for an attacker · ⚠ raises it

Proof of concept & exploit code

Test against your own equipment

curl -s https://vulnpedia.com/cve/CVE-2026-40633/poc.jsonMachine-readable PoC index for this CVE (for automation).

Listed for defensive triage, patch verification, and authorized testing on systems you own. Machine-readable: /cve/CVE-2026-40633/poc.json

Affected

Vendors Dell

Products Powerscale Onefs

Weakness (CWE)

  • CWE-532: : Insertion of Sensitive Information into Log File

CVSS vector

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Known Affected Software Configurations

VendorProductVersion range
DellPowerscale Onefs≥ 9.5.0.0 and < 9.10.1.8
DellPowerscale Onefs≥ 9.11.0.0 and < 9.13.1.0

All CVSS metrics

  • HIGH 7.8 v3.1 · CNA Primary
    CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • HIGH 7.8 v3.1 · NVD Secondary
    CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • MEDIUM 5.5 v3.1 · NVD Primary
    CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Sources: NVD · CVE.org · EPSS