{"schema":"vulnpedia.research/1","cve":"CVE-2026-61677","references":[{"url":"https://github.com/LabRedesCefetRJ/WeGIA/commit/966f7c02585bed1b52d2347269d56f44784c4422","tags":["x_refsource_MISC"],"source":"mitre","sourceId":"GitHub_M","modified":"2026-11-17T21:41:34.295Z","origins":[{"source":"mitre","sourceId":"GitHub_M","modified":"2026-11-17T21:41:34.295Z","tags":["x_refsource_MISC"],"url":"https://github.com/LabRedesCefetRJ/WeGIA/commit/966f7c02585bed1b52d2347269d56f44784c4422"},{"source":"nvd","sourceId":"CVE-2026-61677","modified":"2026-11-17T23:17:58.517","url":"https://github.com/LabRedesCefetRJ/WeGIA/commit/966f7c02585bed1b52d2347269d56f44784c4422"}]},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/pull/1705","tags":["x_refsource_MISC"],"source":"mitre","sourceId":"GitHub_M","modified":"2026-11-17T21:41:34.295Z","origins":[{"source":"mitre","sourceId":"GitHub_M","modified":"2026-11-17T21:41:34.295Z","tags":["x_refsource_MISC"],"url":"https://github.com/LabRedesCefetRJ/WeGIA/pull/1705"},{"source":"nvd","sourceId":"CVE-2026-61677","modified":"2026-11-17T23:17:58.517","url":"https://github.com/LabRedesCefetRJ/WeGIA/pull/1705"}]},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-pvhq-2cf3-xmch","tags":["x_refsource_CONFIRM"],"source":"mitre","sourceId":"GitHub_M","modified":"2026-11-17T21:41:34.295Z","origins":[{"source":"mitre","sourceId":"GitHub_M","modified":"2026-11-17T21:41:34.295Z","tags":["x_refsource_CONFIRM"],"url":"https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-pvhq-2cf3-xmch"},{"source":"nvd","sourceId":"CVE-2026-61677","modified":"2026-11-17T23:17:58.517","url":"https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-pvhq-2cf3-xmch"}]}],"packages":[],"pocCandidates":[],"cataloguedPoc":[],"vendorStatements":[],"sourceTimes":{"primary":"2026-11-17T22:22:15.490Z","cisa-kev":"2026-11-18T00:37:35.027Z","exploitdb":"2026-11-18T00:37:35.027Z","metasploit":"2026-11-18T00:37:35.027Z","zdi":"2026-11-18T00:37:35.027Z","oss-security":"2026-11-18T00:37:35.027Z","full-disclosure":"2026-11-18T00:37:35.027Z","cert-cc":"2026-11-18T00:37:35.027Z","watchtowr":"2026-11-18T00:37:35.027Z","lexfo":"2026-11-18T00:37:35.027Z","google-security-research":"2026-11-18T00:37:35.027Z","vulncheck-initial-access":"2026-11-18T00:37:35.027Z","vulncheck-kev":"2026-11-18T00:37:35.027Z","ghsa":"2026-11-18T00:38:03.601Z","pysec":"2026-11-18T00:38:03.601Z","go":"2026-11-18T00:38:03.601Z","rustsec":"2026-11-18T00:38:03.601Z","nvd":"2026-11-17T23:17:58.517"},"sourceFields":{"schema":"vulnpedia.source-fields/1","primary":{"description":"WeGIA is a web manager for charitable institutions. Prior to 3.8.7, web/html/socio/sistema/processa_edicao_socio.php updates member information without validating an authenticated session. An unauthenticated remote requester who supplies a target member identifier and replacement member fields can modify arbitrary member records, corrupt personal information, and cause loss of data integrity. This issue is fixed in version 3.8.7.","published":"2026-11-17","cwe":[{"id":"CWE-862","name":": Missing Authorization"}],"labels":{"vendors":["LabRedesCefetRJ"],"products":["WeGIA"]},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"}},"nvd":{"description":"WeGIA is a web manager for charitable institutions. Prior to 3.8.7, web/html/socio/sistema/processa_edicao_socio.php updates member information without validating an authenticated session. An unauthenticated remote requester who supplies a target member identifier and replacement member fields can modify arbitrary member records, corrupt personal information, and cause loss of data integrity. This issue is fixed in version 3.8.7.","published":"2026-11-17","cwe":[{"id":"CWE-862","name":"Missing authorization"}],"labels":{"vendors":[],"products":[]},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"}}},"freshness":{"checkedAt":"2026-11-18T00:48:37.980Z","changedAt":"2026-11-18T00:48:37.980Z","pocChangedAt":null,"addedPoCs":[],"removedPoCs":[],"changedPoCs":[]},"labels":{"vendors":["LabRedesCefetRJ"],"products":["WeGIA"]},"evidence":{"version":"2026-11-18T00:48:37.980Z#75647412e57b4f8cb4436473c81dd18c93a0b72f3447c65bf6890eb782130df6","checkedAt":"2026-11-18T00:48:37.980Z","changedAt":"2026-11-18T00:48:37.980Z","pocChangedAt":null}}